Safety instructions |
|
|
Caution safety instructions
Please read safety instructions carefully before lamp operation. |
|
| download PDF |
MVL A ASTRALUX® High pressure mercury vapor lamps "WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." Danger: Do not use this lamp in standard incandescent light bulb sockets, misuse may result in lamp explosion with an associated risk of property damage or personal injury. Caution: If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous shortwave ultraviolet radation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if this glass is struck. Caution: The arc-tube of mercury vapor lamps is designed to operate under high pressure and at temperatures up to 1000° C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment with an associated risk of property damage or personal injury. Safety instructions and lamp operation instructions are packed in the master carton or can be downloaded from this website. |
| download PDF |
SVL A ASTRALUX® High pressure sodium vapor lamps Danger: This lamp must be operated in fixtures designend for use with high pressure sodium lamps. The fixture wattage rating must match the wattage indicate on the outer glass bulb to avoid lamp shattering and hot glass particles. Do not use this lamp in standard incandescent light bulb sockets. Misuse may result in lamp explosion with an associated risk of property damage or personal injury. Caution: If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous shortwave ultraviolet radation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if this glass is struck. Caution: The arc-tube of sodium vapour lamps is designed to operate under high pressure and at temperatures up to 1000° C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment with an associated risk of property damage or personal injury. Safety instructions and lamp operation instructions are packed in the master carton or can be downloaded from this website. |
| download PDF |
MVLI A ASTRALUX® Self ballasted lamps "WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." Caution: No auxiliary electric eqipment necessary. These lamps must be operated in fixtures designed for use with self ballasted mercury lamps. The fixture wattage rating must match the wattage indicate on the outer glass bulb. Misuse may result in lamp explosion with an associated risk of property damage or personal injury. Caution: If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous shortwave ultraviolet radation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if this glass is struck. Caution: The arc-tube of self ballasted mercury lamps is designed to operate under high pressure and at temperatures up to 1000° C and can unexpectedly rupture due to internal or external factors such as a fixture failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment with an associated risk of property damage or personal injury. Safety instructions and lamp operation instructions are packed in the master carton or can be downloaded from this website. |
| download PDF |
HVL A ASTRALUX® Metal halide lamps "WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." Danger: Use only in enclosed fixtures. Do not use this lamp in standard incandescent light bulb sockets, misuse may result in lamp explosion with an associated risk of property damage or personal injury. Caution: If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous shortwave ultraviolet radation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if this glass is struck. Caution: The arc-tube of metal halide lamps is designed to operate under high pressure and at temperatures up to 1000° C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment with an associated risk of property damage or personal injury. Safety instructions and lamp operation instructions are packed in the master carton or can be downloaded from this website. |